
Understanding fire performance
Where our membranes sit on the reaction-to-fire scale
Stamisol A1
Euroclass A1
Stamisol Safe One
Euroclass A2-s1,d0
Proshield®
Euroclass B-s1,d0
A1
Non-combustible
A2
Limited combustibility
B
Limited contribution to fire
C
D
E
F
Not determined
BS EN 13501-1 classifies construction products from A1 to F by how they contribute to a fire under defined test conditions.
What A1, A2-s1,d0 and B-s1,d0 mean
A1
A1 is the highest reaction-to-fire classification. Products achieving this classification are considered non-combustible and make no contribution to fire under the applicable classification criteria.
A2-s1,d0
- A2
- A very limited contribution to fire.
- s1
- The lowest smoke production category.
- d0
- No flaming droplets or particles under the relevant test conditions.
B-s1,d0
- B
- A limited contribution to fire growth under the relevant test conditions.
- s1
- The lowest smoke production category.
- d0
- No flaming droplets or particles under the relevant test conditions.
B-s1,d0 meets the UK building regulations requirement for membrane fire classification. It is the classification Proshield® achieves when adhered to a suitable substrate. The classification should be considered in the context of the tested substrate and installation conditions.
The suitability of a façade membrane depends on the requirements of the individual project, the relevant Building Regulations and the overall façade design. In England, membranes benefit from specific exemptions under Regulation 7, with Approved Document B providing further guidance on their reaction-to-fire performance.
A classification describes the membrane, not the façade
These classifications are not interchangeable, nor do they establish the fire performance of an entire façade system.
The classification of an individual membrane should never be interpreted as proof that the overall façade meets every applicable fire safety requirement.
The complete façade must be considered, including
- Cladding
- Insulation
- Cavity
- Supporting structure
- Membranes
- Fixings
- Cavity barriers

The membrane's job in the building envelope
A façade membrane forms part of the external wall construction and needs to perform in conjunction with the other materials in the building envelope.
When specifying a membrane, consider its
- Water-tightness
- Vapour permeability
- Exposure conditions
- Fire classification
- Compatibility with the proposed construction
Read more +−
Depending on the system, its role may include providing protection against wind-driven rain, helping manage moisture and allowing water vapour to pass through the construction. The precise performance requirements depend on the wall design, substrate, insulation and ventilation strategy.
Installation is equally important. Incorrect detailing, poorly formed joints or unsuitable fixing arrangements can compromise the intended performance of the wall.
The Stamisol and Proshield® product documentation provides the technical information needed to assess each membrane against its intended application.
Have a façade project to discuss?
Send us the build-up, cladding type and joint design. The Fire Solutions team will confirm which membrane applies, what its classification covers and the evidence you need.
Liam Blears
Head of Fire Solutions
Technical services
fire@donlow.co.uk