Our façade membranes

Stamisol A1 documents
Stamisol A1
Non-combustible façade membrane, classified Euroclass A1
Stamisol A1 is a non-combustible façade membrane classified Euroclass A1, the highest reaction-to-fire classification under the European classification system.
- Reaction to fire
- Euroclass A1
- Combustibility
- Non-combustible
- Water-tightness
- W2 (EN 1928)
- Open joints
- Partially open joints up to 10 mm where the membrane is the primary line of weatherproofing
- Intended use
- Specified façade applications
- Weight
- 260 g/m²
- Exposure before cladding
- Cover within 3 months
- Roll size
- 2,656 mm × 32 m
Read more +−
For façade designers and specifiers, the A1 classification provides an important material characteristic when assessing the fire performance requirements of an external wall. It identifies a product that makes no contribution to fire under the conditions of the relevant classification criteria.
The membrane is intended for use in specified façade constructions where non-combustible membrane materials are required. Its suitability must be considered in relation to the façade arrangement and installation conditions covered by the manufacturer’s technical documentation.
Particular attention needs to be paid to the construction behind open or partially open cladding. Stamisol A1 has defined application restrictions where it is used as the primary line of weatherproofing, that is, in front of the insulation layer, including a maximum gap of 10 mm for partially open façade joints. These requirements are important when assessing whether the product is appropriate for a particular cladding design.
For architects and façade consultants, the classification is an important starting point, but it should always be considered alongside the supporting test and classification evidence and the requirements of the complete external wall construction.
Stamisol Safe One
High fire performance with W1 water penetration resistance, classified Euroclass A2-s1,d0
Stamisol Safe One is a specialist façade membrane classified Euroclass A2-s1,d0. This classification identifies a product with a very limited contribution to fire, low smoke production and no flaming droplets or particles under the relevant test conditions.
- Reaction to fire
- Euroclass A2-s1,d0
- Smoke and droplets
- s1, the lowest smoke category; d0, no flaming droplets under test conditions
- Water-tightness
- W1 (EN 13859-2, EN 1928)
- Open joints
- Up to 50 mm and 50% open area
- UV resistance
- Tested to 5,000 hours
- Exposure before cladding
- Cover within 6 months
- Intended use
- Specified ventilated façades, including open-jointed cladding
- Weight
- 310 g/m²
- Roll size
- 2,650 mm × 20 m
Read more +−
The membrane has been developed for use in ventilated façade constructions, including specified open-jointed cladding systems. This makes the relationship between the membrane and external cladding particularly important when developing a façade specification.
Alongside its fire classification, Safe One has W1 water-tightness performance, making it suitable for specified façade applications where protection against water penetration is an important part of the external wall design.
For open-jointed applications, the permitted joint dimensions and exposure conditions must be considered carefully. Safe One is intended for applications with open joints up to 50 mm and 50% open area, subject to the manufacturer’s specified conditions. The supporting construction and installation details must also comply with the relevant product documentation.
For specifiers, Safe One provides a combination of reaction-to-fire classification and water-tightness characteristics that can be considered when designing appropriate ventilated façade systems.

Stamisol Safe One documents

Proshield®
Don & Low’s own self-adhesive façade membrane, classified Euroclass B-s1,d0
Proshield® self-adhesive membrane combines ease of installation with regulatory-compliant reaction-to-fire performance, W1 water penetration resistance and the vapour permeability requirements of modern ventilated façade construction. Designed with ease of installation and airtightness at its core, it offers a membrane solution where compliance and flexibility are key considerations.
- Reaction to fire
- Euroclass B-s1,d0, when adhered to a suitable substrate
- Smoke and droplets
- s1, the lowest smoke category; d0, no flaming droplets under test conditions
- Water-tightness
- W1 (EN 13859-2, EN 1928)
- Fixing
- Self-adhesive, no primer needed
- Airtightness
- Under 0.01 m³/m².h at 50 Pa
- Intended use
- Walls and floors, behind closed-joint cladding only
- Weight
- 270 g/m² with release liner
- Exposure before cladding
- Cover within 3 months
- Roll size
- 1.5 m × 50 m
Read more +−
Proshield® is manufactured by Don & Low and independently certified by KIWA. It bonds directly to the substrate without primers or mechanical fixings, forming a continuous airtight layer across walls and floors, with tapes and preformed corners for junctions and openings.
Adhered to a suitable substrate, Proshield® achieves a Euroclass B-s1,d0 reaction-to-fire classification, which meets the UK building regulations requirement for membrane fire classification. The classification applies where the substrate has a density of 1,350 kg/m³ or more, a minimum thickness of 6 mm and a fire performance of A2-s1,d0 or better, excluding paper-faced gypsum plasterboard.
Its high vapour permeability lets moisture escape from the construction while W1 water penetration resistance protects the wall before and after the cladding is fitted.
How the three membranes differ
All three are designed for façade applications where fire performance is an important consideration, but they are not interchangeable.
| Stamisol A1 | Stamisol Safe One | Proshield® | |
|---|---|---|---|
| Reaction-to-fire classification | Euroclass A1 | Euroclass A2-s1,d0 | Euroclass B-s1,d0 |
| Contribution to fire | None, non-combustible | Very limited | Limited |
| Smoke production | No sub-class at A1 | s1, lowest category | s1, lowest category |
| Flaming droplets or particles | No sub-class at A1 | d0, none | d0, none |
| Water-tightness | W2 | W1 | W1 |
| Sd value (vapour permeability) | 0.1 m | Under 0.12 m | 0.098 m |
| Open joints | Partially open, up to 10 mm, where it is the primary line of weatherproofing | Up to 50 mm and 50% open area | Closed joints only, not open joints |
| Intended use | Specified façade applications needing a non-combustible membrane | Specified ventilated façades, including open-jointed cladding | Walls and floors, adhered to a suitable substrate |
| Exposure before cladding | Cover within 3 months | Cover within 6 months | Cover within 3 months |
| Weight | 260 g/m² | 310 g/m² | 270 g/m² with release liner |
| Roll size | 2,656 mm × 32 m | 2,650 mm × 20 m | 1.5 m × 50 m |
| Temperature resistance | −30°C to +250°C | −40°C to +250°C | Flexible to −40°C |
Figures are from the current Stamisol and Proshield® datasheets and the Proshield® BDA Agrément. Always confirm against the current datasheet and Declaration of Performance. Joint limits are subject to the manufacturer’s documented conditions. The Proshield® classification applies when it is adhered to a suitable substrate.
Which membrane is right for your project?
Consider Stamisol A1 where
- A non-combustible membrane with an A1 classification is required by the project specification.
- The proposed façade construction falls within the product’s documented application scope.
- The installation conditions meet the manufacturer’s requirements.
- The cladding arrangement complies with the product’s restrictions on partially open joints.
Consider Stamisol Safe One where
- An A2-s1,d0 classified membrane is appropriate for the project requirements.
- W1 water-tightness performance is required.
- The proposed construction is a specified ventilated façade system.
- The open-jointed cladding arrangement falls within the manufacturer’s permitted dimensions and conditions.
Consider Proshield® where
- A B-s1,d0 classified membrane meets the project’s regulatory and specification requirements.
- A self-adhesive membrane is wanted for speed of installation and airtightness.
- W1 water penetration resistance is required.
- The substrate meets the conditions of the fire classification.
The final choice should always be based on the project specification and the relevant manufacturer documentation. If you are unsure which product is appropriate, speak to our technical team.
Ask our technical team
What to establish before you specify
A façade membrane can only perform as intended when the product, supporting construction and installation details work together.
- The proposed façade construction and cladding arrangement.
- The supporting substrate and its compatibility with the membrane.
- The fire classification and the scope of the supporting evidence.
- Permitted joint dimensions and exposure conditions.
- The membrane’s water-resistance and moisture-management requirements.
- Fixing arrangements, overlaps, junctions and penetrations.
- The manufacturer’s installation instructions and any project-specific requirements.
The installation guide and relevant technical documentation should be consulted before work begins. Where the proposed construction differs from the documented application, clarification should be obtained from the manufacturer.